Resource Type

Journal Article 355

Conference Videos 1

Year

2023 36

2022 24

2021 35

2020 28

2019 31

2018 25

2017 9

2016 15

2015 23

2014 26

2013 24

2012 10

2011 11

2010 14

2009 11

2008 10

2007 15

2006 1

2005 1

2003 1

open ︾

Keywords

adsorption 23

Adsorption 11

removal efficiency 9

Nitrogen removal 6

Removal 6

Anammox 4

Constructed wetland 4

Removal efficiency 4

phosphorus removal 4

removal 4

Arsenic 3

Biochar 3

Biodegradation 3

Carbon source 3

biosorption 3

Aerobic nitrification 2

Antibiotics 2

Biofilm 2

Biological nutrient removal 2

open ︾

Search scope:

排序: Display mode:

Removal of SO

Xiaolei LI, Chunying ZHU, Youguang MA

Frontiers of Chemical Science and Engineering 2013, Volume 7, Issue 2,   Pages 185-191 doi: 10.1007/s11705-013-1326-5

Abstract: In this work, the removal of SO from gas mixture with air and SO by ammonium bicarbonate aqueous solutionas absorbent was investigated experimentally in a bubble column reactor.concentration of ammonium bicarbonate, the SO inlet concentration of gas phase and the gas flow rate on the removalshorter the lasting time of SO completely removed in gas outlet, and then the faster the decrease in the removalA theoretical model for predicting the SO removal rate has been developed by taking the chemical enhancement

Keywords: SO2 removal     bubble column reactor     removal rate     ammonium bicarbonate     absorbent    

The coupling of sand with ZVI/oxidants achieved proportional and highly efficient removal of arsenic

Sana Ullah, Xuejun Guo, Xiaoyan Luo, Xiangyuan Zhang, Yameng Li, Ziyu Liang

Frontiers of Environmental Science & Engineering 2020, Volume 14, Issue 6, doi: 10.1007/s11783-020-1273-6

Abstract: are highly efficient for arsenic removal. • ZVI/sand/oxidants reduced significantly the Fe2+ leachingof zero-valent iron (ZVI) with common oxidants has recently achieved very rapid and highly efficient removalHowever, the uniform activation of ZVI throughout the column and the proportional removal of target contaminantscolumn inlet and the first sampling point.In a packed column with a 1:20 mixture of ZVI and sand, the average As removal efficiency was 36 (1st

Keywords: Arsenic     ZVI     Sand     Oxidants     Fixed-bed Column     Removal    

Removal of dyes from wastewater by growing fungal pellets in a semi-continuous mode

Tao Lu, Qilei Zhang, Shanjing Yao

Frontiers of Chemical Science and Engineering 2017, Volume 11, Issue 3,   Pages 338-345 doi: 10.1007/s11705-017-1644-0

Abstract: To increase the efficiency of dye removal from wastewater using mycelial pellets, a bubble column reactorEight dyes were tested as dye targets for the adsorption capacity of mycelial pellets and good removalThe bubble column reactor was utilized to study the batch dye-removal efficiency of mycelial pellets.The dye removal rate is 96.4% after 12 h in the first batch and then decreases slowly in the followingThis semi-continuous mode, which consists of commutative processes of dye-removal and re-culture, has

Keywords: dye     mycelial pellets     marine fungus     bubble column reactor     semi-continuous biosorption    

Special Column on

Frontiers of Structural and Civil Engineering 2014, Volume 8, Issue 4,   Pages 323-324 doi: 10.1007/s11709-014-0288-0

Simulation of bubble column reactors using CFD coupled with a population balance model

Tiefeng WANG

Frontiers of Chemical Science and Engineering 2011, Volume 5, Issue 2,   Pages 162-172 doi: 10.1007/s11705-009-0267-5

Abstract: This article gives a selective review of the modeling and simulation of bubble column reactors using

Keywords: bubble column     computational fluid dynamics     bubble breakup and coalescence     population balance model     bubble    

Testing of a full-scale composite floor plate Article

Dennis Lam, Xianghe Dai, Therese Sheehan

Engineering 2019, Volume 5, Issue 2,   Pages 223-233 doi: 10.1016/j.eng.2018.11.021

Abstract:

A full-scale composite floor plate was tested to investigate the flexural behavior and in-plane effects of the floor slab in a grillage of composite beams that reduces the tendency for longitudinal splitting of the concrete slab along the line of the primary beams. This is important in cases where the steel decking is discontinuous when it is orientated parallel to the beams. In this case, it is important to demonstrate that the amount of transverse reinforcement required to transfer local forces from the shear connectors can be reduced relative to the requirements of Eurocode 4. The mechanism under study involved in-plane compression forces being developed in the slab due to the restraining action of the floor plate, which was held in position by the peripheral composite beams; while the secondary beams acted as transverse ties to resist the forces in the floor plate that would otherwise lead to splitting of the slab along the line of the primary beams. The tendency for cracking along the center line of the primary beam and at the peripheral beams was closely monitored. This is the first large floor plate test that has been carried out under laboratory conditions since the Cardington tests in the early 1990s, although those tests were not carried out to failure. This floor plate test was designed so that the longitudinal force transferred by the primary beams was relatively high (i.e., it was designed for full shear connection), but the transverse reinforcement was taken as the minimum of 0.2% of the concrete area. The test confirmed that the primary beams reached their plastic bending resistance despite the discontinuous decking and transverse reinforcement at the minimum percentage given in Eurocode 4. Based on this test, a reduction factor due to shear connectors at edge beams without U-bars is proposed.

Keywords: Floor plate test     Composite beams     Edge beams     Eurocode 4     In-plane effect     Column removal     Robustness    

Special Column on Multiscale Stochastic Finite Element Method

Frontiers of Structural and Civil Engineering 2015, Volume 9, Issue 2,   Pages 105-106 doi: 10.1007/s11709-015-0297-7

Special column: solar energy conversion

Yun Hang HU, Fangming JIN

Frontiers in Energy 2019, Volume 13, Issue 2,   Pages 205-206 doi: 10.1007/s11708-019-0636-9

formation of bimetallic FeNi nanoparticles on sand through green technology: Application for tetracycline removal

Ravikumar KVG, Debayan Ghosh, Mrudula Pulimi, Chandrasekaran Natarajan, Amitava Mukherjee

Frontiers of Environmental Science & Engineering 2020, Volume 14, Issue 1, doi: 10.1007/s11783-019-1195-3

Abstract: . • Removal of tetracycline using GS-FeNi in batch and column study. • Both reductive degradation andsorption played crucial role the process. • Reusability of GS-FeNi showed about 77.39±4.3% removal onThe removal capacity was 181±1 mg/g.The continuous column studies were undertaken in the packed bed reactors using GS-FeNi.The application of GS-FeNi for antibiotic removal was further evaluated in lake water, tap water, and

Keywords: GS-FeNi nanoparticles     Tetracycline removal     Re-usability     Residual toxicity     Column studies    

Seismic tests of post-tensioned self-centering building frames with column and slab restraints

Chung-Che CHOU, Jun-Hen CHEN

Frontiers of Structural and Civil Engineering 2011, Volume 5, Issue 3,   Pages 323-334 doi: 10.1007/s11709-011-0119-5

Abstract: This paper presents a methodology for evaluating the column restraint and beam compression force basedon the column deformation and gap openings at all stories.

Keywords: post-tensioned frame     frame expansion     column restraint     sliding slab     frame test     shake table test    

Experimental and numerical analysis of beam to column joints in steel structures

Gholamreza ABDOLLAHZADEH, Seyed Mostafa SHABANIAN

Frontiers of Structural and Civil Engineering 2018, Volume 12, Issue 4,   Pages 642-661 doi: 10.1007/s11709-017-0457-z

Abstract: formability under extreme loads such as earthquakes are the primary challenges in the modeling of beam-to-columnneural network methods have been presented in order to model the complex hysteresis behavior of beam-to-columnof the neural network, the experiments were carried out on samples with real dimensions of beam-to-columnthe combinational modeling is able to display the complex narrowed hysteresis behavior of the beam-to-column

Keywords: beam to column connections     experiments     component method     neural network model     combinational modeling    

Investigation of the interior RC beam-column joints under monotonic antisymmetrical load

Fei GAO, Zhiqiang TANG, Biao HU, Junbo CHEN, Hongping ZHU, Jian MA

Frontiers of Structural and Civil Engineering 2019, Volume 13, Issue 6,   Pages 1474-1494 doi: 10.1007/s11709-019-0572-0

Abstract: The paper presents numerical findings of reinforced concrete interior beam-column joints under monotonicshear force and thus to increase the shear capacity, prevent the outward buckling of steel bars in column

Keywords: RC beam-column joint     reinforcement ratio in joint core     axial compression ratio     finite element     test    

Study on direct alcohol/ether fuel synthesis process in bubble column slurry reactor

Zhen CHEN, Haitao ZHANG, Weiyong YING, Dingye FANG

Frontiers of Chemical Science and Engineering 2010, Volume 4, Issue 4,   Pages 461-471 doi: 10.1007/s11705-010-0517-6

Abstract: experimental data, and a steady-state one-dimensional mathematical model was further developed in bubble column

Keywords: syngas     alcohol/ether fuel     slurry catalyst     bubble column slurry reactor     global kinetics     mathematical model    

Influence of steel corrosion on axial and eccentric compression behavior of coral aggregate concrete column

Frontiers of Structural and Civil Engineering 2021, Volume 15, Issue 6,   Pages 1415-1425 doi: 10.1007/s11709-021-0786-9

Abstract: To study the behavior of coral aggregate concrete (CAC) column under axial and eccentric compression,the compression behavior of CAC column with different types of steel and initial eccentricity (eei increases, the Nu of CAC columnBesides, the steel corrosion in CAC column is severe, which reduces the steel section and steel strength, and decreases the Nu of CAC column.

Keywords: coral aggregate concrete column     axial compression     eccentric compression     steel corrosion     calculation    

Seismic behavior experimental study of frame joints with special-shaped column and dispersed steel bar

Shuchun LI, Bo DIAO, Youpo SU,

Frontiers of Structural and Civil Engineering 2009, Volume 3, Issue 4,   Pages 378-383 doi: 10.1007/s11709-009-0064-8

Abstract: overcome the problem that steel bars are put too close at a flame joint with special-shaped beam and column, mechanical performance of three groups of six RC flame joints with special-shaped (L, T and+) columnExperimental comparison was conducted between special-shaped (L, T and+) column and normal beams.analysis indicate that the mechanical and seismic behaviors of frame joints with T-shaped and+-shaped columnStiffness degeneration of flame joint with L-shaped column is rather serious due to concrete damage stiffness

Keywords: beam with dispersed steel bar     flame joints with special-shaped beam and column     seismic behavior     scale    

Title Author Date Type Operation

Removal of SO

Xiaolei LI, Chunying ZHU, Youguang MA

Journal Article

The coupling of sand with ZVI/oxidants achieved proportional and highly efficient removal of arsenic

Sana Ullah, Xuejun Guo, Xiaoyan Luo, Xiangyuan Zhang, Yameng Li, Ziyu Liang

Journal Article

Removal of dyes from wastewater by growing fungal pellets in a semi-continuous mode

Tao Lu, Qilei Zhang, Shanjing Yao

Journal Article

Special Column on

Journal Article

Simulation of bubble column reactors using CFD coupled with a population balance model

Tiefeng WANG

Journal Article

Testing of a full-scale composite floor plate

Dennis Lam, Xianghe Dai, Therese Sheehan

Journal Article

Special Column on Multiscale Stochastic Finite Element Method

Journal Article

Special column: solar energy conversion

Yun Hang HU, Fangming JIN

Journal Article

formation of bimetallic FeNi nanoparticles on sand through green technology: Application for tetracycline removal

Ravikumar KVG, Debayan Ghosh, Mrudula Pulimi, Chandrasekaran Natarajan, Amitava Mukherjee

Journal Article

Seismic tests of post-tensioned self-centering building frames with column and slab restraints

Chung-Che CHOU, Jun-Hen CHEN

Journal Article

Experimental and numerical analysis of beam to column joints in steel structures

Gholamreza ABDOLLAHZADEH, Seyed Mostafa SHABANIAN

Journal Article

Investigation of the interior RC beam-column joints under monotonic antisymmetrical load

Fei GAO, Zhiqiang TANG, Biao HU, Junbo CHEN, Hongping ZHU, Jian MA

Journal Article

Study on direct alcohol/ether fuel synthesis process in bubble column slurry reactor

Zhen CHEN, Haitao ZHANG, Weiyong YING, Dingye FANG

Journal Article

Influence of steel corrosion on axial and eccentric compression behavior of coral aggregate concrete column

Journal Article

Seismic behavior experimental study of frame joints with special-shaped column and dispersed steel bar

Shuchun LI, Bo DIAO, Youpo SU,

Journal Article